Aicaigou LogoB2B WikiIndustrial Encyclopedia

Vertical Current Transformer

Updated: 2026-07-20

Overview

Voltage transformers are precision instruments that provide proportional voltage reduction for safe measurement and control in high-voltage circuits. Unlike power transformers, VTs operate at minimal load (burden) to maintain accuracy within specified limits. Their vertical (standing) design optimizes space utilization in switchyards and substations. Modern VTs comply with international standards like IEC 61869 and IEEE C57.13, ensuring interoperability. They serve as critical links between high-voltage equipment and low-voltage protection/metering devices, enabling grid stability and accurate energy accounting.

Structure and Working Principle

安科瑞AKH-0.66/III 3000/5A低压电流互感器 立式方孔型 准确级0.2级安科瑞电气股份有限公司

A typical vertical VT consists of a primary winding connected to the high-voltage line and a secondary winding that delivers reduced voltage to instruments. The laminated core minimizes eddy current losses, while oil/SF6 gas or dry-type insulation ensures dielectric strength. Operating on electromagnetic induction principles, VTs maintain precise voltage ratios (e.g., 10,000V/100V) with phase angles suitable for protective relays. Capacitive voltage transformers (CVTs) combine capacitive dividers with electromagnetic units for extra-high voltage applications above 100kV.

商家经验真实案例 · 安全可信
缝纫机断线不断怎么办
本文针对缝纫机自动断线功能失效的问题,提供三步排查法:从刀片检查到线张力调整,再到传感器校准,帮助快速恢复自动断线功能。

Key Features

Accuracy is paramount, with class 0.2 VTs used for revenue metering and class 3P for protection. Temperature-stable alloys in windings prevent ratio drift. Anti-resonance designs prevent ferroresonance during system disturbances. Compact vertical models save space in GIS (Gas Insulated Switchgear) installations. Dual-secondary windings allow simultaneous connection to metering and protection devices. Some designs incorporate digital outputs for compatibility with smart grid systems.

Application Areas

VTs are indispensable in substations for synchronizing generators, feeding protective relays (distance, differential), and providing inputs to SCADA systems. Industrial plants use them for high-voltage motor monitoring. In renewable energy, they interface solar/wind farm collectors with grid-tie inverters. Railway electrification systems employ special single-phase VTs. Portable test VTs verify protection schemes during commissioning.

Maintenance and Precautions

KDSI直供 立式互感器BE-30CT 150/5A 方孔变压器昆山康的斯仪器仪表有限公司

Regular insulation resistance tests (Megger) detect moisture ingress. Oil-filled units require dissolved gas analysis to identify internal arcing. Annual ratio/phase angle verification ensures metering accuracy. Never operate with an open secondary circuit—this may cause dangerous overvoltages. Ground secondary windings properly to prevent floating potentials. In seismic zones, verify mounting bracket integrity.

商家经验真实案例 · 安全可信
直流电阻低压电流设置
本文探讨直流电阻测试时低压电流的设置原则,解析电流选择对测量精度的影响,并提供不同场景下的实用建议,帮助读者获得准确可靠的测试结果。

B2B Procurement Guide

Specify voltage class (e.g., 36kV, 145kV), accuracy requirements, and environmental conditions (indoor/outdoor, pollution degree). Compare conventional electromagnetic VTs versus CVTs for EHV projects. Leading manufacturers include ABB, Siemens, GE Grid Solutions, and specialty Asian suppliers. Lead times for custom designs may exceed 12 weeks. Request type test reports (IEC 60044) and third-party certification (KEMA, CESI). Bulk orders (50+ units) often qualify for 15-20% discounts.

Related Manufacturers