Aicaigou LogoAicaigou LogoB2B WikiIndustrial Encyclopedia

Liquid Cooling Data Center

Updated: 2026-07-15

Overview

Liquid cooling data centers replace or supplement air-based cooling with liquid coolants to dissipate heat from servers. This method addresses the limitations of air cooling in high-power-density environments, such as those found in AI training clusters or supercomputers. The technology includes direct-to-chip (immersion or cold plate) and rear-door heat exchanger systems. Liquid cooling can achieve up to 90% heat removal efficiency, drastically reducing energy consumption compared to conventional CRAC units. Major adopters include cloud service providers and enterprises requiring sustainable, high-performance infrastructure.

Structure and Working Principle

数据中心专用 316L不锈钢液冷管 Φ10×0.8mm 耐压3MPa 规格支持定制佛山市美龙管业有限公司

A typical system consists of pumps, coolant distribution units (CDUs), and heat exchangers. Coolants absorb heat directly from components (in immersion cooling) or via cold plates attached to CPUs/GPUs. The heated liquid is then circulated to external chillers or dry coolers for dissipation. Dielectric fluids are used in immersion systems to avoid electrical hazards, while water-glycol mixtures are common in indirect cooling. Advanced designs integrate with existing facility cooling loops, enabling hybrid air-liquid configurations for gradual adoption.

商家经验真实案例 · 安全可信
感性负载的诞生之谜
本文揭开感性负载的神秘面纱,从电感特性、电流滞后原理到实际应用场景,用通俗语言解析其产生过程,助你理解电路中的能量“舞蹈”。

Key Features

Energy Efficiency: Cuts cooling energy use by 30–50% compared to air systems, with PUE (Power Usage Effectiveness) often below 1.1. Space Savings: Eliminates bulky air handlers, allowing higher rack densities (50kW+ per rack). Noise Reduction: Near-silent operation versus loud fan arrays. Sustainability: Enables waste heat reuse for district heating or desalination.

Application Areas

Hyperscale Cloud Facilities: Google and Microsoft deploy liquid cooling for AI workloads. HPC Labs: Used in supercomputers like Fujitsu's Fugaku. Edge Data Centers: Compact liquid systems suit space-constrained sites. Cryptocurrency Mining: Immersion cooling extends hardware lifespan in mining rigs. Modular Data Centers: Prefabricated liquid-cooled pods offer plug-and-play deployment.

Maintenance and Precautions

304不锈钢流体管 液冷316集分水器管 储能数据中心厂家 定制浙江荣瑞管道科技有限公司

Routine inspections for coolant purity and leaks are critical. Dielectric fluids degrade over time and require monitoring for particulate contamination. Corrosion inhibitors must match metallurgy (e.g., aluminum vs. copper). Emergency protocols should address coolant spills, including containment kits and non-conductive absorbents. Training for staff on handling liquid-cooled hardware is essential to prevent electrical or slip hazards.

商家经验真实案例 · 安全可信
电源检测三步法
本文提供三种实用的电源检测方法,包括直观检查、电压测试和带载测试,帮助快速判断电源工作状态,避免设备因电源故障受损。

B2B Procurement Guide

When sourcing liquid cooling solutions, assess total cost of ownership (TCO), including installation, coolant replacement, and energy savings. Pilot testing with a single rack is recommended before full deployment. Key vendors include Vertiv, Schneider Electric, and specialized firms like LiquidStack. Contracts should cover performance guarantees, maintenance SLAs, and compatibility with existing IT gear. Leasing options are available for capex-constrained buyers.

Related Manufacturers