Integrated UV Flame Detector 102T

Updated: 2026-07-15

Overview

The Integrated UV Flame Detector 102T is a specialized device used for detecting flames in industrial settings. It employs ultraviolet (UV) sensing technology to identify the presence of flames by detecting the UV radiation they emit. This detector is particularly useful in environments where traditional flame detection methods may fail due to interference or harsh conditions. Designed for reliability, the 102T model is commonly deployed in boilers, furnaces, and other combustion systems. Its compact and rugged construction ensures durability, while its high sensitivity minimizes the risk of false alarms. The detector is widely used in industries such as oil & gas, power generation, and chemical processing, where flame detection is critical for safety and operational efficiency.

Structure and Working Principle

C7012G1019 220V 美国honeywell 火焰探测器 紫外线监测 C7012A1194上海韦凌控制设备有限公司

The 102T detector consists of a UV-sensitive sensor housed in a stainless steel casing, which protects it from environmental hazards. The sensor detects UV radiation emitted by flames, typically in the 180-260 nm wavelength range. When UV radiation is detected, the sensor sends a signal to the control system, triggering alarms or shutdown procedures as needed. The working principle relies on the fact that flames emit UV radiation during combustion. The detector's optical components are designed to filter out other light sources, ensuring accurate detection. Advanced models may include additional features such as self-testing capabilities and adjustable sensitivity settings to enhance performance in diverse conditions.

商家经验真实案例 · 安全可信
速腾点火开关线束接法
本文详解速腾车型点火开关两根线束的正确连接方法,包括线束功能区分、接线步骤及注意事项,帮助车主或维修人员安全完成操作。

Key Features

The Integrated UV Flame Detector 102T boasts several key features that make it a preferred choice for industrial applications. Its high sensitivity allows it to detect even small flames, ensuring early warning and rapid response. The detector's fast response time, typically under 3 seconds, is critical for preventing accidents and minimizing damage. Another notable feature is its resistance to false alarms, achieved through advanced filtering technology that distinguishes flame UV radiation from other sources. The rugged stainless steel casing provides protection against dust, moisture, and corrosive environments, making it suitable for use in harsh industrial settings. Additionally, the detector is designed for easy installation and integration with existing safety systems.

Application Areas

The 102T detector is widely used in industries where flame detection is essential for safety and operational continuity. In the oil & gas sector, it is employed in refineries, pipelines, and storage facilities to monitor for accidental fires. Power plants utilize these detectors in boilers and turbines to ensure safe combustion processes. The chemical processing industry also relies on UV flame detectors to monitor reactors and furnaces, where uncontrolled flames can lead to catastrophic incidents. Other applications include incinerators, industrial heaters, and aerospace testing facilities. The detector's versatility and reliability make it a staple in environments where flame detection is non-negotiable.

Maintenance and Precautions

SGMJV-04AAA 伺服电机 脉冲驱动器无刹车标准法兰电机 331125020029辉亚格(北京)数据智能科技有限公司

Regular maintenance is crucial to ensure the optimal performance of the 102T detector. This includes periodic cleaning of the optical components to remove dust and debris that could impair sensitivity. Calibration should be performed as recommended by the manufacturer to maintain accuracy. Precautions include avoiding direct exposure to sunlight or other strong UV sources, which could cause false alarms or damage the sensor. The detector should be installed in a location where it has a clear line of sight to the potential flame source, free from obstructions. Additionally, environmental conditions such as temperature and humidity should be considered during installation to prevent premature wear or malfunction.

商家经验真实案例 · 安全可信
高能火花塞功率
本文深入解析高能火花塞的功率特性,探讨其与传统火花塞的区别,以及在实际应用中的优势与注意事项,帮助读者全面了解高能火花塞的性能。

B2B Procurement Guide

When procuring the Integrated UV Flame Detector 102T, buyers should prioritize suppliers with a proven track record in industrial safety equipment. Key considerations include the detector's detection range, sensitivity settings, and compatibility with existing control systems. Custom configurations may be available to meet specific operational needs. Buyers should also evaluate the supplier's after-sales support, including availability of spare parts and technical assistance. Bulk purchasing may offer cost savings, but it's essential to ensure consistent quality across units. Requesting product certifications and compliance with industry standards (e.g., ATEX, IECEx) can further validate the detector's suitability for hazardous environments.