Cat6 Single Shielded Network Cable

Updated: 2026-07-17

Overview

Cat6 Single Shielded Network Cable (SFTP) is a twisted-pair Ethernet cable engineered for high-speed data transmission in environments prone to electromagnetic interference (EMI). It combines four twisted copper pairs with an overall aluminum foil shield, differentiating it from unshielded (UTP) or double-shielded (S/FTP) variants. The cable adheres to ANSI/TIA-568-C.2 and ISO/IEC 11801 standards, ensuring compatibility with Gigabit and 10-Gigabit networks over distances up to 55 meters. Designed for B2B applications, it is widely deployed in data centers, factory automation, and structured cabling systems where signal integrity is critical. The shielding mitigates crosstalk and external noise, making it suitable for installations near power lines or heavy machinery.

Structure and Working Principle

室内线缆六类单屏蔽网线 无氧铜超六类线非屏蔽天津市电缆总厂橡塑电缆厂

The cable’s construction includes 23 AWG oxygen-free copper (OFC) conductors, each insulated with high-density polyethylene (HDPE). The four twisted pairs are wrapped in a bonded aluminum foil shield, which reflects and absorbs EMI. A drain wire ensures proper grounding of the shield, while a PVC or LSZH jacket provides mechanical protection. Shielding works by creating a Faraday cage around the conductors, diverting external electromagnetic fields away from the signal-carrying pairs. This design preserves bandwidth efficiency, allowing the cable to achieve 250 MHz performance. Termination requires shielded RJ45 connectors to maintain end-to-end EMI protection.

商家经验真实案例 · 安全可信
MPO是什么光缆
本文解析MPO光缆的定义、结构特点及应用场景,帮助读者了解这种高密度光纤连接解决方案在数据中心和通信网络中的重要性。

Key Features

1. **EMI Resistance**: The foil shield reduces interference by up to 40 dB compared to UTP cables, critical in industrial settings. 2. **High Bandwidth**: Supports 10GBASE-T (10 Gbps) up to 55 meters and 1000BASE-T (1 Gbps) up to 100 meters. 3. **Durability**: PVC jackets offer abrasion resistance; LSZH variants are available for fire-safe installations. 4. **Standards Compliance**: Meets TIA-568-C.2, ISO/IEC 11801, and RoHS directives. Unlike Cat6a, Cat6 SFTP balances cost and performance for medium-distance applications. Its flexibility suits tight spaces, though bending radius should exceed four times the cable diameter.

Application Areas

1. **Data Centers**: Used for server-to-switch connections where EMI from power distribution units is prevalent. 2. **Industrial Ethernet**: Deployed in factories for PLCs, motor controls, and robotic systems. 3. **Smart Buildings**: Ensures reliable PoE (Power over Ethernet) delivery for IP cameras and access points. In healthcare, shielded Cat6 cables prevent MRI or imaging equipment interference. For outdoor use, UV-resistant jackets are recommended. The cable is incompatible with legacy Cat5e infrastructure due to higher impedance requirements.

Maintenance and Precautions

安普北创 六类单屏蔽网线 CAT6纯铜0.57芯双绞线网络UTP宽带跳线北京江海洋线缆有限公司

1. **Grounding**: Always terminate shields to grounded RJ45 connectors or patch panels to avoid antenna effects. 2. **Bending**: Avoid sharp bends (>90°) to prevent shield cracking, which compromises EMI protection. 3. **Testing**: Use cable certifiers like Fluke DSX-5000 to verify insertion loss and return loss post-installation. Storage should be in dry, coiled conditions to prevent kinking. For long-term installations, consider CMR-rated cables for riser applications or CMP-rated for plenum spaces. Regularly inspect connectors for oxidation.

商家经验真实案例 · 安全可信
RS485通信:终端电阻配置指南
本文解析RS485通信中终端电阻的配置方法,包括何时需要配置、如何选择阻值及安装位置,帮助读者轻松解决信号反射问题。

B2B Procurement Guide

1. **Volume Discounts**: Bulk purchases (e.g., 305-meter reels) typically reduce costs by 15–30%. 2. **Certifications**: Request TIA/EIA compliance reports and third-party test data (e.g., UL verification). 3. **Customization**: Suppliers offer pre-terminated lengths, colored jackets, or LSZH materials for project-specific needs. Leading manufacturers include Belden, Panduit, and Siemon. Spot-check conductor purity with a ohmmeter (target ≤9.38 Ω/100m at 20°C). For reference, 24 AWG versions are cheaper but limited to shorter runs.

Related Manufacturers