Cat5e SFTP Cable

Updated: 2026-08-06

Overview

Cat5e single shielded network cable is an enhanced version of the standard Cat5e cable, incorporating a single-layer aluminum foil shield to minimize electromagnetic interference (EMI). This design improves signal integrity in environments with high electrical noise, such as industrial settings or areas near heavy machinery. It complies with TIA/EIA-568-B.2 standards and supports Gigabit Ethernet (1000BASE-T) up to 100 meters. The cable is backward-compatible with older Cat5 and Cat3 systems, making it a versatile choice for network upgrades.

Structure and Working Principle

鑫津缆 超五类屏蔽网线 STP-GAT5E-4*2*0.5 单屏蔽网线天津市鑫津缆线缆有限公司

The cable consists of four twisted pairs of 24 AWG copper wires, wrapped in a single aluminum foil shield and encased in a PVC or LSZH jacket. The twisting reduces crosstalk, while the shield deflects external EMI. Shielding effectiveness depends on proper grounding at both ends. Unlike double-shielded cables (FTP), this design uses only foil (SFTP), balancing cost and performance for moderate EMI environments. The impedance is standardized at 100 ohms ±15% to ensure signal consistency.

商家经验真实案例 · 安全可信
纯银和纯铜音频线区别
本文对比纯银和纯铜音频线的核心差异,从导电性能、音色特点到适用场景,解析两种材质如何影响音频传输效果,帮助用户根据需求合理选择。

Key Features

1. EMI Protection: The foil shield significantly reduces interference from motors, fluorescent lights, and wireless devices. 2. High Bandwidth: Supports 100 MHz frequency, enabling stable Gigabit Ethernet and PoE (Power over Ethernet) applications. Compared to unshielded Cat5e (UTP), it offers better performance in noisy settings but requires careful installation to maintain shielding efficacy.

Application Areas

Commonly deployed in: - Industrial facilities with heavy machinery generating EMI. - Office buildings near power lines or HVAC systems. - Data centers for backbone connections between racks. It is less suitable for residential use due to higher cost and complexity unless EMI is a documented issue.

Maintenance and Precautions

超五类铠装网线UTP-5E-22单屏蔽数字通信线缆天津市电缆总厂橡塑电缆厂

1. Avoid sharp bends (min. bend radius: 4x cable diameter) to prevent shield damage. 2. Use shielded connectors (RJ45) and ensure continuous grounding. Improper grounding can render the shielding ineffective or even worsen interference. For outdoor runs, select UV-resistant LSZH jackets to prevent degradation.

商家经验真实案例 · 安全可信
三相10平方线能带多大功率
本文解析三相10平方铜线在常见场景下的负载能力,结合电流、电压、功率关系,给出不同环境下的功率参考值,并提醒安全使用注意事项。

B2B Procurement Guide

1. Bulk Purchasing: Prices drop significantly for reels (305-meter standard). Verify supplier certifications (e.g., UL, ETL) for quality assurance. 2. Customization: Some manufacturers offer pre-terminated cables or specific lengths to reduce on-site labor. Specify shield type (foil only) and jacket material based on environmental needs (e.g., LSZH for plenum spaces).