Aicaigou LogoAicaigou LogoB2B WikiIndustrial Encyclopedia

AO Process Tank

Updated: 2026-08-06

Overview

The AO Process Purification Tank is a specialized wastewater treatment system integrating anaerobic (A) and aerobic (O) stages to achieve high-efficiency removal of organic pollutants and nitrogen compounds. Developed to address stringent environmental regulations, it is widely adopted in municipal sewage plants, industrial facilities, and decentralized treatment projects. The system leverages microbial communities to decompose contaminants sequentially, ensuring compliance with discharge standards. Compared to conventional activated sludge systems, the AO process reduces energy consumption by 20–30% while improving nutrient removal. Its modular design allows scalability for small communities or large industrial complexes. The technology is particularly effective for treating wastewater with high organic loads, such as food processing or chemical manufacturing effluents.

Structure and Working Principle

组合式污水净化槽分散式农村生活污水处理设备ao工艺环保1级b标准潍坊冠科环保科技有限公司

The tank consists of two main compartments: an anaerobic zone for hydrolysis/acidification and an aerobic zone for nitrification. In the anaerobic section, facultative bacteria break down complex organics into simpler compounds while releasing phosphorus. Wastewater then flows into the aerobic zone, where nitrifying bacteria convert ammonia to nitrate, and heterotrophic microbes further degrade organic matter. Aeration is carefully controlled in the aerobic chamber using diffusers or mechanical surface aerators to maintain optimal dissolved oxygen levels (2–4 mg/L). Internal recycling pumps return mixed liquor from the aerobic to the anaerobic zone to facilitate denitrification. This cyclical process achieves total nitrogen removal rates of 70–90% and COD reduction exceeding 95% in properly maintained systems.

商家经验真实案例 · 安全可信
农田灌溉水质要求
本文探讨农田灌溉用水的水质关键指标及其影响,包括悬浮物、盐分、重金属等要素对作物生长和土壤健康的潜在风险,并提供实用的水质优化建议。

Key Features

1. Dual-stage biological treatment: Combines the advantages of anaerobic and aerobic degradation for comprehensive pollutant removal. 2. Energy-efficient operation: The anaerobic stage reduces aeration requirements, lowering power consumption by 25–40% compared to purely aerobic systems. 3. Compact footprint: Vertical flow designs and integrated clarifiers minimize space requirements, making it suitable for urban installations. 4. Smart control compatibility: Modern units feature IoT-enabled sensors for real-time monitoring of pH, DO, and sludge concentration. Additional benefits include low sludge production (30% less than conventional systems) and adaptability to fluctuating loads. Some advanced models incorporate membrane filtration (AO-MBR) for tertiary treatment, producing reusable water quality.

Application Areas

Municipal wastewater plants: Medium-sized communities (5,000–100,000 PE) frequently adopt AO systems to meet Class 1A discharge standards for nitrogen and phosphorus. The technology is cost-effective for upgrading existing facilities without expanding footprint. Industrial applications: Food processing, pharmaceutical, and textile industries utilize AO tanks to handle high-BOD wastewater. Petrochemical plants employ corrosion-resistant FRP models for organic compound removal. In rural areas, prefabricated AO units serve scattered populations where sewer networks are unavailable. Specialized uses include landfill leachate treatment and aquaculture water recycling. The system's tolerance to load variations makes it ideal for seasonal operations like tourist sites or agricultural processing plants.

Maintenance and Precautions

东易环保 一体化AO工艺净化槽自动运行快速安装河北东易环保设备有限公司

Routine maintenance involves daily checks of aeration equipment, weekly sludge settling tests, and monthly inspections of pumps and diffusers. Maintain MLSS concentration at 3,000–5,000 mg/L and SRT between 10–20 days for optimal performance. Anaerobic zones require periodic mixing to prevent sludge accumulation. Critical precautions include: - Avoiding sudden pH shocks (maintain 6.5–8.5) - Preventing toxic substance inflow (e.g., heavy metals, chlorinated solvents) - Ensuring proper temperature control (15–35°C) - Calibrating online monitors quarterly Winter operation demands insulation or submerged heaters in cold climates. Annual professional servicing should include membrane cleaning (for AO-MBR systems) and biofilm carrier inspection.

商家经验真实案例 · 安全可信
全自动玻璃钢工字钢
本文解析全自动玻璃钢工字钢的特性与应用场景,对比传统金属工字钢的差异化优势,并探讨其生产工艺中的创新技术要点。

B2B Procurement Guide

When sourcing AO purification tanks, verify the supplier's experience with similar-scale projects. Key evaluation criteria: 1. Hydraulic retention time (HRT): Standard systems require 8–12 hours total (2–3h anaerobic, 6–9h aerobic) 2. Material selection: Stainless steel (SUS304/316) for corrosive wastewater; FRP for lightweight installations 3. Aeration efficiency: Look for fine-bubble diffusers with ≥30% oxygen transfer rate 4. Compliance certifications: CE, ISO 9001, and local environmental approvals Request performance guarantees for effluent quality (e.g., <15mg/L COD, <5mg/L TN). Consider modular designs for future expansion. Leading manufacturers typically offer 5–10 year warranties on tanks and 2 years on mechanical components. Shipping costs for large FRP units may reach 8–12% of equipment price.