0.16a Series Thermal Overload Relay
Overview
The 0.16A Series Thermal Overload Relay is an electromechanical device engineered to protect motors from damage caused by prolonged overcurrent or phase failure. Operating on the principle of bimetallic thermal deflection, it responds to heat generated by excessive current, triggering a mechanical trip to disconnect the circuit. This series is particularly valued for its low-current sensitivity (0.16A), making it suitable for small motors in precision applications like medical equipment or laboratory instruments. As a critical link in motor starter assemblies, it integrates seamlessly with contactors and circuit breakers. Compliant with IEC/EN 60947-4-1 standards, it ensures reliable performance in diverse industrial environments, from food processing plants to automated assembly lines.
Structure and Working Principle
The relay's core component is a bimetallic strip that bends predictably when heated by motor current passing through a heater coil. At preset temperature thresholds (adjustable via calibration dial), the strip activates a trip mechanism to open the contactor's control circuit. Auxiliary contacts provide signaling for remote monitoring systems. Modern variants incorporate ambient temperature compensation to prevent false tripping in fluctuating environments. The 0.16A model's compact housing typically includes test/reset buttons and LED status indicators. Its DIN rail mounting design simplifies installation in control panels, while screw terminals accommodate conductor sizes up to 2.5mm².
Key Features
1. **Precision Protection**: 0.16A trip range with ±10% accuracy ensures protection for delicate low-power motors. 2. **Durability**: Silver alloy contacts withstand >100,000 mechanical operations; UL94 V-0 rated housing resists flame propagation. 3. **Versatility**: Class 10 trip curve (fast response) suits most applications; optional manual/auto reset modes. 4. **Diagnostic Capabilities**: Built-in trip indication assists troubleshooting; some models offer communication-ready interfaces for Industry 4.0 integration. Notably, the relay's fail-safe design guarantees trip activation even during power loss, while its reverse-phase protection feature guards against motor rotation errors.
Application Areas
Primary applications include: - **Medical Devices**: Protects motors in MRI cooling systems and surgical robots where downtime is critical. - **Laboratory Equipment**: Safeguards centrifuges and precision pumps in pharmaceutical labs. - **HVAC Systems**: Used in small fan coil units and ventilation damper actuators. - **Industrial Automation**: Defends servo motors in packaging machinery and CNC tool changers. These relays are particularly favored in OEM applications requiring UL508/CSA C22.2 No. 14 certification. Their low thermal dissipation makes them ideal for densely packed control cabinets.
Maintenance and Precautions
**Routine Checks**: Annually verify trip calibration using a current injection tester; clean contacts with electrical-grade solvent if arcing occurs. Monitor for discoloration indicating overheating. **Installation Notes**: Maintain minimum 10mm clearance between relays for heat dissipation. Avoid mounting near transformers or other heat sources. Always de-energize circuits before servicing. **Failure Symptoms**: Frequent nuisance tripping may signal incorrect sizing or failing motor bearings. Failure to trip could indicate welded contacts – replace immediately. Document trip events to identify load pattern issues.
B2B Procurement Guide
**Technical Specifications**: Request third-party test reports for trip time curves at 600% overload. Confirm auxiliary contact ratings (typically 5A resistive). **Supplier Evaluation**: Prioritize manufacturers with ISO 9001-certified production lines. Request mean time between failure (MTBF) data – quality relays exceed 100,000 operations. **Logistics**: Standard lead times range 2–4 weeks; stock models may carry MOQs of 50–100 units. Consider modular designs allowing field replacement of trip units without rewiring. **Cost Factors**: Bulk purchases (500+ units) often yield 15–20% discounts. Compare total cost of ownership – cheaper relays may lack self-test features, increasing maintenance expenses.
Related Manufacturers
- 主营:变频器、框架断路器、塑壳断路器、接近开关、双电源开关、接触器
- 主营:断路器、接触器、接近开关、BB热过载继电器、编码器
- 主营:低压管、熔断器、线电子、继电器、控制器、保护器、接触器、信号灯、变频器、调压器、电磁铁、计数器、断路器、电能表、hd11f-40038、hd11f-20038、hd11f-60038、组合开关、人民电器、hd11f-100038、开关插座、家用电表、单控面板、插卡电表、普通端子
- 主营:热过继电器、变送器、限位开关、行程开关
- 主营:电磁阀、plc备件、温控仪、相序继电器、热过载继电器、触摸屏、电开关、传感器、扫描仪、启动柜、扩展机、模块plc、调节器、控制器、保护器、变频器、编码器、光电开光、行程开关、接近开关、软启动器、交流接触器、框架断路器、塑壳断路器
- 主营:接触器、断路器、传感器、热继热过载继电器、防雷器、接近开关、光电开关、浪涌保护器、双电源转换开关、行程开关、编码器
- 主营:电气
- 主营:西门子断路器、西门子熔断器、西门子接触器、西门子继电器、欧姆龙固态继电器、欧姆龙终端继电器、欧姆龙小型中间继电器、西门子3SU系列按钮、欧姆龙接近传感器、欧姆龙光纤传感器、欧姆龙光电开关、欧姆龙温度传感器、欧姆龙旋转编码器、欧姆龙微动开关、欧姆龙限位开关、欧姆龙安全门开关、欧姆龙数字温控器
- 主营:plc模块、处理器、传感器、凯帆热过载继电器、接近开关、填充模块、锂电池模块、运动控制器、编码器模块、以太网模块
- 主营:全新plc、制动器、cpu模块、继电器、电磁阀、i/o模块、触摸屏、脱扣器、控制器、接触器、变频器、接近开关、断路器、行程开关、小型断路器、塑壳断路器、LC1D、框架断路器、施耐德、西门子模块、图尔克(TURCK)、P+F(倍加福)、常熟、EZD、NSX
- 主营:接近开关、安全栅、接触器、交流继电器、时间继电器、变频器、传感器、保护器、断路器、plc模块、4000w电机、电磁阀、光电开关、限位开关、驱动器、连接线、可调器
- 主营:断路器、软启动器、漏电保护电气、继电器、开关电源、模块、编码器、变频器、触摸屏、马达保护器、多功能表、行程限位开关、接触器、接近开关、隔离开关、双电源自动转换开关、伺服电机、驱动器、温控器、线圈、传感器
- 主营:ABB微型断路器、ABB接触器、ABB塑壳断路器、ABB继电器、ABB变频器、WAGO接线端子、WAGO工业接口模块、HARTING工业连接器、浩亭工业以太网交换机、人民电器微型断路器、SICK工业传感器
- 主营:继电器、变频器、风机水泵、功率模块
- 主营:接触器、plc模块、传感器、继电器、编码器、变频器、控制器、软启动、断路器、驱动器、光电开关、电源模块、电机马达、断路开关、网络模块、扩展模块、开关电源、输出模块、三相四极、感应开关、接近开关、伺服电机、工控设备、空气开关、转换模块